Your Safer Source for Science
All-In-One Science Solution
Your Safer Source for Science
;
Address P.O. Box 219 Batavia, IL 60510
Phone 800-452-1261
Fax
Email [email protected]
Item #: OB2179 
alternative codes
Alternative Product Codes: 702015,S94792J,1292747,SB45461

Price: $150.00

5+ items: $142.05

In Stock.

Flinn Scientific Economy Choice electronic Balances are great balances at an unbeatable price! Unique design that is both rugged and practical—perfect for everyday use. This digital balance will withstand years of student use.

See more product details

Other Options

Item# OB2179 OB2163 OB2164 OB2180
Size 1000 g x 1 g 250 g × 0.1 g 2500 g x 1 g 3000 g x 1 g
Price $150.00 $182.00 $140.00 $142.00
5+ items
Sold by each
$142.05
$172.42
$132.58
$134.74
Enter number of items

Product Details

Great digital balances at an unbeatable price! The Flinn Scientific Economy Choice electronic Balance offer a heavy-duty weight cell that protects the digital balance from overload damage, a large LCD display, stainless steel pan and an advanced microprocessor that makes it the best in its class. Two-button operation makes the balance simple and very easy to use. Features overload and low battery indicators. Unique design that is both rugged and practical—perfect for everyday use. This digital balance will withstand years of student use. Pan size is 12 cm. Digital balance Includes AC adapter. 1-year limited warranty.

 

 

 

Understanding Electronic Balances 

Electronic balances, also known as digital balances or precision balances, are essential devices for measuring the mass of substances with utmost accuracy. Unlike traditional manual beam balances, electronic balances employ advanced sensor technology and digital displays to provide precise and quick measurements. These devices are a cornerstone of scientific experimentation and are utilized across various disciplines, from chemistry and biology to earth science and physics. 

What is an Electronic Balance Used for in a Science Lab?  

The applications of electronic balances in the high school science lab are diverse and indispensable: 

Chemistry: Electronic balances are used for accurately measuring the mass of reagents, chemicals, and compounds. This precision is critical for stoichiometry, titration, and determining reaction yields. 

Biology: In biology experiments, electronic balances play a crucial role in weighing samples, such as dissected organisms, to record their mass accurately. This data is fundamental for biological investigations. 

Physics: In physics experiments, the accurate measurement of mass is essential for studying the forces and properties of objects. Electronic balances ensure precise data collection. 

Environmental Science: For environmental science studies, electronic balances are used to measure the mass of samples such as soil, water, and air pollutants. These measurements are vital for understanding environmental impacts. 

Key Features to Consider 

When selecting an electronic balance for your high school science lab, it's essential to consider the following key features: 

Capacity: Determine the maximum weight the balance can measure. Make sure it accommodates the range of substances you'll be working with. 

Precision: Electronic balances offer varying levels of precision, usually expressed as the number of decimal places. Choose a balance with the precision appropriate for your experiments. 

Taring Function: This feature allows you to set the balance to zero with a container on it, making it easier to weigh substances without the container's mass. 

Calibration: Look for a balance with a user-friendly calibration process to ensure accuracy. Regular calibration is crucial for reliable results. 

Digital Display: Opt for a balance with a clear and easy-to-read digital display. Some models even feature touchscreen interfaces for convenience. 

Portability: Consider the size and portability of the balance to ensure it fits your lab space and can be easily moved if necessary. 

Durability: While your budding young scientists may be passionate, they may not always be as careful as they could be. Choosing a balance that will withstand regular use by students is important.  

Calibration and Accuracy 

Calibration is a critical aspect of maintaining the accuracy of electronic balances. Even high-quality balances require periodic calibration to ensure precise measurements. Here's a simplified guide to calibrating your electronic balance: 

Preparation: Ensure the balance is clean and free from any debris or substances that might affect measurements. 

Zero Calibration: Turn on the balance and allow it to stabilize. Press the tare or zero button to set it to zero with no load on the pan. 

Standard Calibration Weights: Use certified standard weights to calibrate the balance. These weights are known to be accurate and are used as a reference. Place the standard weight on the balance and allow it to measure the weight. 

Adjustment: If the balance doesn't display the correct weight, use the adjustment or calibration function on the balance to match the displayed weight to the known weight of the standard calibration weight. 

Verification: To ensure accuracy, perform multiple calibrations with different standard weights and average the results. 

Regular Maintenance: Calibrate the balance at regular intervals, depending on usage and manufacturer recommendations. 

Safety Guidelines 

Safety is a paramount consideration when working with electronic balances in the high school science lab. Here are some essential safety guidelines: 

Stability: Ensure the balance is placed on a stable, flat surface to prevent tipping over and causing accidents. 

Handling Substances: Use appropriate containers, such as beakers or weigh boats, when measuring substances to prevent spills or contamination of the balance. 

Avoid Overloading: Do not exceed the maximum capacity of the balance to avoid damage and maintain accuracy. 

Cleanliness: Keep the balance clean and free from spilled substances. Use a brush or a lint-free cloth to remove any debris. 

Handling Weights: When calibrating or verifying the balance, handle standard weights with care and precision to avoid damaging them. 

No Direct Heat: Avoid placing hot objects directly on the balance pan, as extreme temperature changes can affect its accuracy. 

Best Practices 

To maximize the utility and longevity of your electronic balance, consider these best practices: 

Zeroing: Always zero the balance before use, and ensure it returns to zero after removing any containers or substances from the pan. 

Gentle Handling: Handle the balance and its components (such as the pan and draft shield) with care to prevent damage. 

Avoid Drafts: Electronic balances are sensitive to air currents. Use a draft shield to protect against drafts, which can affect measurements. 

Record Data: Keep a meticulous record of measurements, including the substance being weighed, its mass, and any additional relevant information. 

Regular Maintenance: Clean the balance as needed, and follow manufacturer guidelines for maintenance and service. 

Electronic balances are indispensable tools in the high school science lab, enabling precise measurements critical for various experiments across scientific disciplines. By understanding their applications, key features, calibration, safety guidelines, and best practices, you can harness the power of electronic balances to enhance the quality and accuracy of your experiments.  And if you are looking for electronic precision balances or other instruments or equipment for your lab, make sure to check out Flinnsci.com.