SECTION 1 — CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
Methylparaben Solution
Flinn Scientific, Inc. P.O. Box 219, Batavia, IL 60510 (800) 452-1261 Chemtrec Emergency Phone Number: (800) 424-10017
Signal Word DANGER
SECTION 2 — HAZARDS IDENTIFICATION
Hazard class: Flammable liquids (Category 2). Highly flammable liquid and vapor (H225). Keep away from heat, sparks, open flames, and hot surfaces. No smoking (P210).
Hazard class: Acute toxicity, oral and dermal (Category 3). Toxic if swallowed or in contact with skin (H301+H311). Do not eat, drink or smoke when using this product (P270).
Hazard class: Skin and serious eye damage, corrosion or irritation (Category 2, 2A). Causes skin and serious eye irritation (H315+H319).
Hazard class: Specific target organ toxicity, single exposure (Category 1). Causes damage to organs (H370). Do not breathe mist, vapors or spray (P260).
Pictograms
SECTION 3 — COMPOSITION, INFORMATION ON INGREDIENTS
Component Name
CAS Number
Formula
Formula Weight
Concentration
Methylparaben Methyl alcohol
Synonyms: Mold inhibitor
99-76-3 67-56-1
C8H8O3 CH3OH
152.16 32.04
0.3% 99.7%
SECTION 4 — FIRST AID MEASURES
If exposed or concerned: Call a POISON CENTER or physician (P307+P311). If inhaled: Remove victim to fresh air and keep at rest in a position comfortable for breathing. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do so. Continue rinsing (P305+P351+P338). If eye irritation persists eyes: Get medical advice or attention (P337+P313). If on skin or hair: Immediately remove all contaminated clothing. Rinse skin with water (P303+P361+P353). Remove immediately all contaminated clothing (P361). Wash contaminated clothing before reuse (P363). If swallowed: Rinse mouth. Immediately call a POISON CENTER or physician (P301+P310+P330).
SECTION 5 — FIRE FIGHTING MEASURES
Class IB flammable liquid due to methyl alcohol content. Flash point: 11 °C; Flammable limits: lower is 6.0% and upper is 36%; Autoignition temperature: 464 °C Dangerous fire risk. When heated to decomposition, may emit toxic fumes. In case of fire: Use a tri-class dry chemical fire extinguisher (P370+P378). Hazardous combustion products: Poisonous gases including formaldehyde are produced in fire (due to methanol content)
NFPA Code
None established
SECTION 6 — ACCIDENTAL RELEASE MEASURES
Remove all ignition sources and ventilate area. Contain spill with sand or other inert absorbent material; deposit in sealed bag or container. See Sections 8 and 13 for further information.
SECTION 7 — HANDLING AND STORAGE
Flinn Suggested Chemical Storage Pattern: Organic #2. Store with alcohols, glycols, amines and amides. Store in a dedicated flammables cabinet. If a flammables cabinet is not available, store in Flinn Saf-Stor™ can. Keep container tightly closed (P233). Keep cool (P235). Take precautionary measures against static discharge (P243).
SECTION 8 — EXPOSURE CONTROLS, PERSONAL PROTECTION
Wear protective gloves, protective clothing, and eye protection (P280). Wash hands thoroughly after handling (P264). Exposure guidelines: (as methyl alcohol) PEL/TLV 200 ppm (OSHA, ACGIH), STEL 250 ppm (ACGIH) Readily absorbed through the skin.
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
Clear colorless liquid. Alcohol odor.
SECTION 10 — STABILITY AND REACTIVITY
Avoid contact with acids, acid chlorides, acid anhydrides, oxidizers, reducers, and alkali metals. Shelf life: Indefinite, if stored properly.
This Safety Data Sheet (SDS) is for guidance and is based upon information and tests believed to be reliable. Flinn Scientific, Inc. makes no guarantee of the accuracy or
completeness of the data and shall not be liable for any damages relating thereto. The data is offered solely for your consideration, investigation, and verification. The
data should not be confused with local, state, federal or insurance mandates, regulations, or requirements and CONSTITUTE NO WARRANTY. Any use of this data and
information must be determined by the science instructor to be in accordance with applicable local, state or federal laws and regulations. The conditions or methods of
handling, storage, use and disposal of the product(s) described are beyond the control of Flinn Scientific, Inc. and may be beyond our knowledge. FOR THIS AND OTHER
REASONS, WE DO NOT ASSUME RESPONSIBILITY AND EXPRESSLY DISCLAIM LIABILITY FOR LOSS, DAMAGE OR EXPENSE ARISING OUT OF OR IN ANY WAY CONNECTED WITH THE HANDLING, STORAGE, USE OR DISPOSAL OF THIS PRODUCT(S).
Consult your copy of the Flinn Science Catalog/Reference Manual for additional information about laboratory chemicals.