logo

Pyridine Safety Data Sheet (SDS)

SDS #: 663
Revision Date: May 16, 2014
SECTION 1 — CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Pyridine

Flinn Scientific, Inc. P.O. Box 219, Batavia, IL 60510 (800) 452-1261
Chemtrec Emergency Phone Number: (800) 424-10200
Signal Word
DANGER
SECTION 2 — HAZARDS IDENTIFICATION
Hazard class: Flammable liquids (Category 2). Highly flammable liquid and vapor (H225). Keep away from heat, sparks, open flames, and hot surfaces. No smoking (P210).

Hazard class: Acute toxicity, oral (Category 4). Harmful if swallowed, in contact with skin or if inhaled (H302+P312+P332). Do not eat, drink or smoke when using this product (P270).
Pictograms
SECTION 3 — COMPOSITION, INFORMATION ON INGREDIENTS
Component Name CAS Number Formula Formula Weight Concentration
Pyridine

110-86-1 C5H5N
79.1
SECTION 4 — FIRST AID MEASURES
Call a POISON CENTER or physician if you feel unwell (P312).
If inhaled: Remove victim to fresh air and keep at rest in a position comfortable for breathing (P304+P340).
If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do so. Continue rinsing.
If on skin: Wash with plenty of water (P302+P352). Wash contaminated clothing before reuse (P363).
If swallowed: Rinse mouth.Call a POISON CENTER or physician if you feel unwell (P302+P301+P312).
SECTION 5 — FIRE FIGHTING MEASURES
Class 1B flammable liquid.
Flash point: 20 °C Flammable limits: Lower: 1.8% Upper: 12.4% Autoignition Temperature: 482 °C
When heated to decomposition, may emit toxic fumes.
In case of fire: Use a tri-class dry chemical fire extinguisher (P370+P378).
NFPA Code
H-3
F-3
R-0
SECTION 6 — ACCIDENTAL RELEASE MEASURES
Remove all ignition sources and ventilate area. Contain spill with sand or other inert absorbent material; deposit in sealed bag or container. See Sections 8 and 13 for further information.

SECTION 7 — HANDLING AND STORAGE
Flinn Suggested Chemical Storage Pattern: Organic #2. Store with alcohols, glycols, amines and amides.
Store in a dedicated flammables cabinet. If a flammables cabinet is not available, store in Flinn Saf-Stor™ can.
Keep container tightly closed (P233). Keep cool (P235). Use only in a hood or well-ventilated area (P271). Use explosion-proof electrical and ventilating equipment (P241).
SECTION 8 — EXPOSURE CONTROLS, PERSONAL PROTECTION
Wear protective gloves, protective clothing, and eye protection (P280). Wash hands thoroughly after handling (P264). Use only in a hood or well-ventilated area (P271).
Exposure guidelines: PEL 5 ppm (OSHA); TLV 1 ppm (ACGIH); IDLH 1000 ppm
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
Slight yellow or colorless liquid. Nauseating odor.
Soluble: Water and many organic solvents
Boiling point: 115 °C
Melting point: -42 °C
Specific gravity: 0.9819
Vapor density: 2.72
Vapor pressure: 20 mmHg
SECTION 10 — STABILITY AND REACTIVITY
Avoid contact with acids, acid chlorides, oxidizers, chloroformates.
Shelf life: Good, if stored properly.
SECTION 11 — TOXICOLOGICAL INFORMATION
Acute effects: Toxic, severe irritant, coughing, chest pains, difficulty in breathing, and GI disturbances.
Chronic effects: Possible mutagen
Target organs: Liver, kidneys
ORL-RAT LD50: 891 mg/kg
IHL-RAT LC50: 28,500 mg/m3/1H
SKN-RBT LD50: 1121 mg/kg
SECTION 12 — ECOLOGICAL INFORMATION
Data not yet available.
SECTION 13 — DISPOSAL CONSIDERATIONS
Please review all federal, state and local regulations that may apply before proceeding.
Flinn Suggested Disposal Method #5 is one option.
SECTION 14 — TRANSPORT INFORMATION
Shipping name: Pyridine. Hazard class: 3, Flammable liquid. UN number: UN1282.
SECTION 15 — REGULATORY INFORMATION
TSCA-listed, EINECS-listed (203-809-9), RCRA code U196.
SECTION 16 — OTHER INFORMATION
This Safety Data Sheet (SDS) is for guidance and is based upon information and tests believed to be reliable. Flinn Scientific, Inc. makes no guarantee of the accuracy or completeness of the data and shall not be liable for any damages relating thereto. The data is offered solely for your consideration, investigation, and verification. The data should not be confused with local, state, federal or insurance mandates, regulations, or requirements and CONSTITUTE NO WARRANTY. Any use of this data and information must be determined by the science instructor to be in accordance with applicable local, state or federal laws and regulations. The conditions or methods of handling, storage, use and disposal of the product(s) described are beyond the control of Flinn Scientific, Inc. and may be beyond our knowledge. FOR THIS AND OTHER REASONS, WE DO NOT ASSUME RESPONSIBILITY AND EXPRESSLY DISCLAIM LIABILITY FOR LOSS, DAMAGE OR EXPENSE ARISING OUT OF OR IN ANY WAY CONNECTED WITH THE HANDLING, STORAGE, USE OR DISPOSAL OF THIS PRODUCT(S).
Consult your copy of the Flinn Science Catalog/Reference Manual for additional information about laboratory chemicals.