Autoclave Accessories, continued
Autoclave Support Base
Support base will raise the electrically heated autoclave (AP1004) above your laboratory bench top so that no damage is done to the bench top. Made of heavy cast aluminum, this valuable safety device allows air to circulate freely under the very hot appliance.
Bacterial Strips for Autoclave Verification
Monitor your autoclave’s performance using bacterial strips! Indicators consist of Bacillus stearothermophilus spores saturated on paper strips, individually placed into envelopes. B. stearothermophilus is a highly resistant, thermophilic species that can grow at temperatures 65 °C and above. To verify autoclave performance, simply place indicators in the autoclave so that they are exposed to the steam. After the cycle is complete, inoculate the strip in tube of broth and incubate at 55– 60 oC for at least 48 hours. If no growth occurs, you can rest assured your autoclave is functioning properly!
Indicator Tape
Indicator tape for sterilization. Tape indicates through striations when the sterilization process is complete. 3⁄4" x 165'.
1-800-452-1261
10
flinnsci.com
                   Catalog No.
  Description
  Price/Each
   AP1005
 Autoclave Support Base
   $94.00
 Autoclave Support Base AP1005
Indicator Tape AP10081, etc.
 Catalog No.
  Description
  Price/Each
   FB2146
 Bacterial Strips for Autoclave Verification
   $37.75
    Catalog No.
   Description
  Type
  Price/Each
   AP10081
Indicator Tape
  Dry Heat Sterilization
  $35.00
 AP10082
  Autoclave Heat Sterilization
  12.00
    Use an Autoclave Safely
• Never autoclave a closed container.
• Glassware must be free of scratches, chips, breaks and cracks.
• Use only autoclavable plastic (e.g., polymethylpentene, poly-
propylene, PTFE).
• Containers should not be more than half full.
• Do not allow the pressure to exceed 20 psi.
• Pressure should be at zero and the control valve open before
loosening the cover wing nuts.
• Follow the manufacturer’s instructions and maintenance recommendations.
• When autoclaving liquids, release the pressure slowly; use slow exhaust to prevent liquid boil-over.
 Bacteria Strips for Autoclave Verification FB2146
 Timer/Controller
See pages 221–222.
  A Guide to Laboratory
Glassware Poster
By: Andy Brunning & Compound Interest, Cambridge, UK
Make getting to know glassware easy for your students with this color- ful visual aid! Laminated, 24" x 36".
 Catalog No.
  Description
  Price/Each
   AP9296
 A Guide to Laboratory Glassware Poster
   $22.95
   






































   10   11   12   13   14